The influence of ODM technique on the radiation dose received by patients during head CT scan

dc.contributor.authorSobczyk, Joanna
dc.contributor.authorPusz-Sapa, Aleksandra
dc.contributor.authorWojtasik, Aneta
dc.contributor.authorGaweł, Greta
dc.contributor.authorTruszkiewicz, Adrian
dc.contributor.authorGuz, Wiesław
dc.date.accessioned2019-04-03T11:31:41Z
dc.date.available2019-04-03T11:31:41Z
dc.date.issued2018
dc.description.abstractIntroduction. Computed tomography (CT) is inexpensive radiological examination of high diagnostic effectiveness. However, common use of CT tests has led to increased exposure to ionizing radiation in the population. Aim. To assess the effect of organ dose modulation (ODM) technique on the radiation dose received by patients during head CT scan. Material and methods. A retrospective analysis of 120 tests in two groups of patients who had CT scans without and with ODM. Every group consisted of 60 people (30 women and 30 men in each). The ability to perform tests in two algorithms (without and with ODM) resulted from the fact that after installing the apparatus, tests were carried out using standard technique, and only then the ODM function was launched. Results. We found that during examinations with ODM, patients received a reduced dose of ionizing radiation. The mean DLP value with ODM is 9.4% lower than the mean DLP value without ODM by comparing the tests with and without contrasting agent. The mean DLP value obtained in men using ODM was 11.9% lower than the mean dose without ODM, and in women this difference was 6.6%. Conclusion. The mean DLP value received by men with ODM was by 11.9% lower than the mean dose without ODM, and in women this difference was 6.6%. Patients receive a lower dose both in tests with and without a contrasting agent compared to the tests where ODM was not used. A statistical significance of the obtained results was found.pl_PL.UTF-8
dc.identifier.citationEuropean Journal of Clinical and Experimental Medicine T. 16, z. 3 (2018), s. 198–203pl_PL.UTF-8
dc.identifier.doi10.15584/ejcem.2018.3.4
dc.identifier.eissn2544-1361
dc.identifier.issn2544-2406
dc.identifier.urihttp://repozytorium.ur.edu.pl/handle/item/4485
dc.language.isoengpl_PL.UTF-8
dc.publisherWydawnictwo Uniwersytetu Rzeszowskiegopl_PL.UTF-8
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Międzynarodowe*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectorgan dose modulationpl_PL.UTF-8
dc.subjectcomputed tomographypl_PL.UTF-8
dc.subjectprotection against ionizing radiationpl_PL.UTF-8
dc.titleThe influence of ODM technique on the radiation dose received by patients during head CT scanpl_PL.UTF-8
dc.typearticlepl_PL.UTF-8
Pliki
Oryginalny pakiet
Aktualnie wyświetlane 1 - 1 z 1
Ładowanie...
Obrazek miniatury
Nazwa:
4 sobczyk-the influence.pdf
Rozmiar:
359.62 KB
Format:
Adobe Portable Document Format
Opis:
Pakiet licencji
Aktualnie wyświetlane 1 - 1 z 1
Ładowanie...
Obrazek miniatury
Nazwa:
license.txt
Rozmiar:
1.22 KB
Format:
Item-specific license agreed upon to submission
Opis: