Comparison of conventional syringe anesthesia and three computer-aided anesthesia systems (Quicksleeper, SleeperOne, and The Wand)

dc.contributor.authorSingh, Nisha
dc.contributor.authorWyzga, Sylvia
dc.contributor.authorYune, Jessica
dc.contributor.authorMathur, Gauri
dc.contributor.authorBłochowiak, Katarzyna
dc.date.accessioned2022-12-09T09:55:25Z
dc.date.available2022-12-09T09:55:25Z
dc.date.issued2022-12
dc.description.abstractIntroduction and aim. The purpose of this study was to compare different Computerized-Controlled Local Anesthetic Delivery (CCLAD) systems to one another in addition to the conventional syringe. Material and method. The CCLAD systems chosen for this study are the Quicksleeper, SleeperOne, and The Wand. These are discussed in categorical objectives, including the following: duration of anesthesia, analgesic effect, locality; anxiolytic effect; advantages and disadvantages; comfort and safety of use; limitations. Analysis of the literature. The research found that many factors influence the effectiveness of dental injections, and the CCLAD systems are designed to reduce the ones that cause negative experiences. The injection systems are unique in their descriptions but show many similarities. Conclusion. The research concluded that each device has its advantages and disadvantages and that its efficiency depends on outlying factors, independent of the injection system used.eng
dc.identifier.citationEuropean Journal of Clinical and Experimental Medicine T. 20, z. 3 (2022), s. 272–283
dc.identifier.doi10.15584/ejcem.2022.3.4
dc.identifier.eissn2544-1361
dc.identifier.urihttps://repozytorium.ur.edu.pl/handle/item/8321
dc.language.isoeng
dc.publisherWydawnictwo Uniwersytetu Rzeszowskiego
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 Poland
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/pl/
dc.subjectcomputerized-controlled local anesthetic delivery
dc.subjectconventional Syringe
dc.subjectlocal anesthesia
dc.subjectQuicksleeper
dc.subjectSleeper- One
dc.subjectThe Wand
dc.titleComparison of conventional syringe anesthesia and three computer-aided anesthesia systems (Quicksleeper, SleeperOne, and The Wand)
dc.typereview

Pliki

Oryginalny pakiet

Aktualnie wyświetlane 1 - 1 z 1
Ładowanie...
Obrazek miniatury
Nazwa:
4 singh-comparison.pdf
Rozmiar:
274.33 KB
Format:
Adobe Portable Document Format

Pakiet licencji

Aktualnie wyświetlane 1 - 1 z 1
Nazwa:
license.txt
Rozmiar:
1.3 KB
Format:
Item-specific license agreed upon to submission
Opis: